Home / Technical Data Sheet / ALLEN® 8200BC

ALLEN® 8200BC

High impact, fire rated PC/ABS, high gloss biocompatible medical grade sheet

ALLEN® 8200BC is a bio compatible FR PC/ABS medical grade sheet with high impact strength and high heat deflection

ALLEN® 8200BC meets Federal Motor Vehicle Safety Standard No. 302 (FMVSS 302) and meets UL94 V-0, 5V criteria when tested under laboratory conditions.

  • Covers and Housings
  • Fan Shrouds
  • Healthcare / Medical Equipment
  • MRI panels
  • Instrument Panels
  • Custom color matching
  • Good forming properties
  • Edge trim easily used for future orders
  • High gloss finish • Meets many medical specifications

SEKISUI KYDEX®, LLC is committed to ensuring that its products can be manufactured, transported, stored, used, disposed and recycled with an appropriate regard for safety, health and environmental protection. We support the safe handling of our products. Please contact our Technical Service department at 800.682.8758 for resources or visit our website: http://www.kydex.com. For Material Safety Data Sheets, please call 800.325.3133.

Property Test Method Typical Value1
PHYSICAL
Specific Gravity ASTM D792 1.19
Water Absorption, 24hr ASTM D570 0.50%
MECHANICAL
Tensile Strength ASTM D638 10,000 psi 69 MPa
Tensile Modulus ASTM D638 384,000 psi 2,650 MPa
Flexural Modulus ASTM D790 381,000 psi 2626.9 MPa
Flexural Stress at 5% Strain ASTM D790 14,600 psi 100.7 MPa
Notched Izod Impact Resistance ASTM D256 12.0 ft-lbs/in 640.6 J/m
Notched Izod Impact Resistance, -20°F (-29°C) ASTM D5420 3.31 ft-lbs/in 176.7 J/m
THERMAL
Heat Deflection Temperature (HDT) @264 psi (1.8 MPa), unannealed ASTM D648 208 °F 98 °C
Heat Deflection Temperature (HDT) @66 psi (0.45 MPa), unannealed ASTM D648 223 °F 106 °C
Coefficient of Thermal Expansion (MD) ASTM E831 37.8 μin/in/°F 68 μm/m/°C
ELECTRICAL
Dielectric Strength, oil ASTM D149 889 V/mil 35 kV/mm
FLAMMABILITY
Underwriters Laboratories., Inc ® Component Recognition UL Standard 942 V-0, 5V @ 0.060” (1.5mm)
Motor Vehicle Safety Standard FMVSS 302 PASS
1 Values based upon 0.125” (3.17mm) sheet unless otherwise specified. 2 Tested under independent laboratory conditions Resin tested only according to ISO 10993-5 and ISO 10993-10 for contact with uncompromised skin Not intended for specification purposes.